Lightning Tracker App Store

Storm basics

Wet-bulb temperature calculator

November 19, 2026 · 5 min read

Two thermometers, one with a wet wick, on a fence rail on a humid afternoon

Enter air temperature, relative humidity and actual station pressure to estimate ventilated wet-bulb temperature in °F and °C. The National Weather Service (NWS) El Paso publishes the psychrometric equation used here; this calculator solves that equation in reverse. The result describes evaporative cooling of a wetted thermometer, not the wet-bulb globe temperature used to assess workplace heat.

The wet-bulb temperature is the lowest temperature evaporation can cool air to; this estimate uses the psychrometric equation the National Weather Service publishes.

Estimated ventilated wet-bulb temperature. This is not wet-bulb globe temperature (WBGT), a heat safety limit, a forecast or medical advice.

Enter three measurements from the same conditions

The calculator takes dry-bulb air temperature in °F, relative humidity as a percent, and actual station pressure in inches of mercury. The National Weather Service (NWS) El Paso wet-bulb procedure uses those three inputs, converting temperature to °C and pressure to hectopascals (hPa) before calculation. “Dry bulb” means the ordinary air-temperature reading; the NWS describes a wet-bulb reading as a moistened thermometer exposed to airflow. The difference comes from evaporative cooling of the wetted bulb.

Use pressure measured at your location. The NWS El Paso input page explicitly asks for actual station pressure, not an altimeter setting. A sea-level-adjusted pressure may look familiar in a weather report, but it is not the pressure this equation calls for. The form has no pressure default. If you do not have the actual value, leave the field blank instead of inventing one. The displayed result repeats the entered pressure so you can spot a unit or transcription error.

What the result does not decide

The number is an estimated ventilated wet-bulb temperature from entered observations, not a measured reading, a forecast, a personal heat limit or permission to stay outdoors. The NWS El Paso forward procedure recommends a Skew-T diagram and describes its own calculator as approximate. This page’s solver uses another NWS equation in reverse; it does not reproduce the forward diagram procedure. Incorrect or mismatched input measurements can therefore give a precise-looking but misleading tenth of a degree.

Wet bulb is not wet-bulb globe temperature (WBGT). OSHA says WBGT measurement combines dry-bulb, natural wet-bulb and globe thermometers to account for air temperature, humidity, radiant heat and air movement at a worksite. OSHA recommends an on-site WBGT monitor for workplace environmental heat, so the single number here cannot replace that assessment. For storm-related work decisions, a lightning plan for outdoor work addresses when a crew stops and where it goes; this calculator supplies neither a lightning observation nor a clearance.

How the calculation works

The NWS El Paso inverse psychrometric formula starts with dry-bulb temperature T, ventilated wet-bulb temperature Tw and station pressure P. It computes the vapor pressure at the wet bulb, then subtracts a pressure-dependent term proportional to the dry-to-wet temperature difference. Its saturation-vapor-pressure expression is 6.112 × exp[17.67 × temperature / (temperature + 243.5)], with temperature in °C and pressure in hPa. The constants 6.112, 17.67, 243.5, 0.00066 and 0.00115 are from that NWS document; they are not fitted from this page’s examples.

Our calculator first multiplies saturation vapor pressure at the entered air temperature by relative humidity divided by 100. It then finds the wet-bulb temperature that makes the NWS inverse equation return that vapor pressure. The root search is our implementation, not a forward formula published by the NWS. Internal calculations use °C and hPa without intermediate rounding; the display rounds the final °F and °C values separately to one decimal place. At 100% relative humidity, the result equals air temperature, as the NWS description of wet bulb says it should.

Two worked estimates

At 86°F (30°C), 50% relative humidity and 29.92 inHg actual station pressure, the widget displays about 71.8°F (22.1°C). Our calculation converts 29.92 inHg to about 1013.2 hPa, forms vapor pressure from the 50% humidity, and solves the NWS inverse equation for the temperature of the wetted bulb. The result is below the 86°F dry-bulb reading because evaporation cools the bulb. In the NWS description, the dry and wet readings approach each other as humidity rises; at 100% they coincide.

At 95°F (35°C), 70% relative humidity and the same entered 29.92 inHg, the widget displays about 86.2°F (30.1°C). This example shows a smaller dry-to-wet gap in more humid air, but the two examples change both air temperature and humidity, so the gap is not an isolated humidity experiment. For an isolated pressure comparison at 86°F and 50%, entering 23.624 inHg gives about 70.9°F (21.6°C); that is a different actual-pressure assumption, not a way to correct a sea-level report. All three numbers are outputs of this calculator’s equation, not NWS published example results.

Input limits and a subfreezing result

The form accepts 32–122°F (0–50°C), 1–100% relative humidity and 14.765–32.484 inHg (500–1100 hPa) station pressure. Those are this product’s input bounds, not NWS validity limits. An empty field keeps the entry prompt on screen. If every field is filled but any value is nonnumeric or out of range, the widget lists the accepted ranges without a result. A calculated wet bulb below 32°F (0°C) instead shows that this water-based equation does not handle ice-bulb conditions. A failed numerical solution tells you to check the measurements. A valid output always reminds you to use actual station pressure rather than a sea-level pressure or altimeter setting.

A relative-humidity calculator answers the separate input question when you have air temperature and dew point, while a dew-point calculator finds the temperature where water vapor begins to condense. This tool uses relative humidity as an input and returns only an estimated wet bulb; it does not calculate either neighbor’s output.

Where evaporation meets thunderstorms

The NWS Spotter’s Field Guide says rain falling through dry air can evaporate before reaching the ground; that virga cools the air, makes it denser and can produce gusty winds. The evaporative cooling in a wetted thermometer is a useful way to understand that physical direction, but this ground-level calculation cannot predict a downburst in a thunderstorm. The rain that evaporates before the ground also explains why dry ground does not mean a storm lacks lightning. A wet-bulb result cannot locate or time afternoon thunderstorms.

Lightning Tracker is an iPhone app that shows recently detected strikes on a live map, including the nearest strike’s distance, direction and age. The calculator on this page uses only the three values you enter; the site provides no live weather reading here.

Not a substitute for official weather warnings.

If you hear thunder, seek shelter even if the app shows no nearby strike.

Sources